Rs232 and tcp/ip commands, Routing commands – Intelix FLX-44 User Manual
Page 27

FLX-44 Installation Guide
27
Routing Commands
RS232 and TCP/IP Commands
RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None
TCP/IP Settings: User defined IP address (default IP address: 192.168.0.178), port 8080
There is either a period (.) or a semicolon (;) at the end of each command. These characters must be present for
the command to process correctly.
There are no spaces between any of the characters in the command string.
xx
= Input Number (input 2 would be 02)
yy
= Output Number (output 3 would be 03)
<CR>
= Carriage return (Hex 0D)
<LF>
= Line Feed (Hex 0A)
Description
Command
Response
Route input xx to output yy
xxByy.
AV: xx->0yy<CR><LF>
Route input xx to all outputs
xxAll.
xx To All<CR><LF>
Route inputs to corresponding outputs
All#.
All Through.<CR><LF>
Route input xx to multiple outputs yy
Number of outputs is unlimited; each
output must be separated by a comma (,)
xxByy,yy.
xxVyy,yy<CR><LF>
Turn off all outputs
All$.
All Closed.<CR><LF>
Turn off specific output yy
yy$.
AV: yy Closed. <CR><LF>
Output yy routing status
Statusyy.
V: xx->0yy<CR><LF>
Routing status of all inputs.
Status.
V: xx->0yy<CR><LF>
(Repeating sequence starting with
output 1, output 2, etc�)
02All.
Route Video and Audio from input 2 to all outputs
04$.
Turn off Video and Audio for output 4
02B03.
Route Video and Audio from input 2 to output 3
03B02,04.
Route Video and Audio from input 3 to outputs 2 and 4
Examples: