background image

FLX-44 Installation Guide

14

Connect RS232 Control

In addition to traditional RS232 control, the FLX-44 has an advanced RS232 control mechanism which allows RS232

tunneling and routing through the HDBaseT output port to control remote devices. Intelix recommends using the

DIGI-HD60C-R for installations which require RS232 extension.

See page 27 for all available control commands for the FLX-44.

Matrix Control via RS232

Remote RS232 Control via Tunneling

The RS232 control port requires a standard straight-through serial cable for operation. The default settings for the

RS232 port are:

• 9600 baud

• 8 Data Bits

• 1 Stop Bit

• Parity = none

Connect a standard straight-through serial cable with DE9 connector

between the RS232 port on the FLX-44 and the controller.

Discrete remote control of remote display devices is possible by connecting an RS232 output of a control system

to the 3-pole terminal block on the output of the matrix. A compatible HDBaseT with control receiver is required

to pass the control signals to the display devices.

To use the RS232 extension capabilities of the FLX-44, connect the TX, ground, and RX control signal wires to the

removable 3-pole terminal block. Consult the manual of the control device(s) to determine which pins the TX/RX

signals are carried on. Be sure to always connect TX to RX and RX to TX.

Tx

Rx

RXD

GND

TXD

FLX-44

Controller

Rx

Tx

TXD

GND

RXD

DIGI-HD60C-R

Display

Advertising