13 appendix – JUMO 902931 Wtrans Receiver with Wireless Data Transmission Operating Manual User Manual

Page 97

Advertising
background image

97

13 Appendix

Electrical data

Environmental influences

Case

Voltage supply

AC 110 to 240 V +10/-15 %, 48 to 63 Hz
or AC/DC 20 to 30 V, 48 to 63 Hz

Power consumption

12 VA

Electrical connection

Screw terminals up to 2.5 mm

2

Electrical safety

According to DIN EN 61010, part 1
overvoltage category III,
pollution degree 2,
for installation in a control cabinet according to DIN EN 50178

Galvanic isolation

The voltage supply is galvanically isolated from the analog out-
puts, relays, and interfaces.

Test voltage

AC 3700 V

Ambient temperature range

-20 to +50 °C without condensation
(even with close mounting)

Storage temperature range

-30 to +70 °C

Temperature influence

≤ ±

0.005 %

1

/K;

per K deviation from the reference temperature of 22 °C (

±

3 K)

1

All accuracy specifications in % from the measuring range end value of 20 mA or 10 V.

Resistance to climatic conditions

Rel. humidity

85 % without condensation

Acc. to DIN EN 60721-3-3 3K3

Vibration resistance

Max. 1 g at 10 to 55 Hz according to DIN IEC 60068-2-6

EMC
- Interference emission
- Interference immunity
- Radio frequency spectrum

DIN EN 61326-1
Class A – for industrial applications only –
industrial requirements
ETSI EN 300220-1 and ETSI EN 300220-2

Material

Polyamide

Flammability class

UL 94 V-2

Dimensions with
antenna screw connection
(W × H × D)

22.5 mm × 115.0 mm × 117.8 mm

Mounting

DIN rail 35 mm × 7.5 mm according to EN 60715

Protection type

IP20 according to DIN EN 60529

Installation position

Vertical

Weight

Approx. 200 g