KEYPAD

N

O

P

Q

R

S

M

M

Up/Down

• In Calibration Mode: the buttons are used to adjust the

measured cable length to match the known cable length

within the range of 25ft to 1000ft (10m to 300m).

• In Tone Mode: the buttons select a cadence (HI, LO, HL1,

HL2).

N

Memory

The Memory button is used to store up to two NVP values

for testing purposes.
• Short presses of the Memory button toggles between the

two memory storage locations: M1 and M2.

• A long press (two seconds) of the button stores an NVP

value in the selected storage location.

O

+

A long press (two seconds) of the Memory and Calibration

buttons simultaneously toggles between units of

measurement (feet and meters).

P

Calibration

The Calibration button allows you to discover the NVP

value based on an inputted cable length.
• Short presses of the Calibration button adjust cable

length in increments of 50ft or 20m within the range of

50ft to 1,000ft or 20m to 300m.

• A long press (two seconds) of the Calibration button

aborts Calibration mode and enters Test Mode.

Q

Test

The Test button initiates length testing on the connected cable.
• A short press runs a single test on demand.
• A long press (two seconds) of the button starts loop

testing. Pressing any button (except Power) stops loop

testing (or the unit turns off after 3 minutes).

R

Tone

The Tone button allows you to trace cables by sound.
• A short press of the button transmits an audio tone from

the unit through the connected cable.

• Subsequent presses of the Tone button toggle between

Test and Tone modes.

• An analog tone probe (not included) must be used in

order to hear the tone.

S

Power

• A long press (two seconds) of the Power button powers

on the Ranger™ TDR.

• Subsequent presses of the button toggle the backlight on and off.
• A long press (two seconds) of the button powers off the

Ranger™ TDR.