Electrical installation
Three−phase AC motor operation on a frequency inverter
l
33
BA 33.0005−EN 2.0
Minimum requirements for basic
insulation according to IEC/EN
60664−1 (CE)
Higher requirements for UL design
Motor diameter
3.87 mm
6.4 mm
< 178 mm
9.5 mm
> 178 mm
ƒ
The terminal box has to be free of foreign bodies, dirt, and humidity.
ƒ
All unused cable entries and the box itself must be sealed against dust and water.
6.2
Three−phase AC motor operation on a frequency inverter
(
Stop!
Motors MF
LMA are only suitable for frequency inverter operation.
L−force three−phase AC motors M
LLMA are suitable for the operation on Lenze frequency
inverters and can be combined without restriction.
If another inverter is used for operation, the voltage peaks (U
pp
) for given rise times (t
R
) as
shown in the diagram must not be exceeded.
MT−MDXMA−005.iso/dms
Fig. 2
Permissible voltage peaks for frequency inverter operation (characteristic according to IEC
60034−25, curve A)