3 feedback system, 4 plug connectors, Brake connection – Lenze MDxMA-MHxMA-MFxMA-MDERA-MHERA Three-phase AC motors User Manual

Page 36: Electrical installation, Stop

Advertising
background image

Electrical installation

Plug connectors
Feedback system

6

l

36

BA 33.0005−EN 2.0

6.3.3

Feedback system

Resolver

Terminal

Designation

Meaning

B1
B2

+ Ref
− Ref

Transformer windings
(reference windings)

B3

Not assigned

B4
B5

+ Cos
− Cos

Stator winding cosine

B6
B7

+ Sin
− Sin

Stator winding sine

B8

Not assigned

Incremental encoder / sin/cos absolute value encoder with Hiperface

Terminal

Designation

Meaning

B1
B2

+ U

B

GND

Supply +
Mass

B3
B4

A
A

Track A / + COS
Track A inverse / − COS

B5
B6

B
B

Track B / + SIN
Track B inverse / − SIN

B7
B8

Z
Z

Zero track / + RS485
Zero track inverse / − RS485

B10

1)

Shield − housing

Shield − incremental encoder

1)

The terminal is not assigned if insulation at N−end shield of the motor has been selected!

6.4

Plug connectors

(

Stop!

ƒ

Tighten the coupling ring of the connector.

ƒ

If plugs without SpeedTec bayonet nut connectors are used, the connector
boxes for the power / encoder / fan connections must be secured by O−rings
if loadings by vibration occur:
– M17 connector box with O−ring 15 x 1.3 mm
– M23 connector box with O−ring 18 x 1.5 mm

Plug−in connectors (plug/connector box) with SpeedTec bayonet nut
connectors are vibration−proof.

ƒ

If SpeedTec bayonet nut connectors are used, O−rings must be removed (if
any)!

ƒ

Never disconnect plugs when voltage is being applied! Otherwise, the plugs
could be destroyed! Inhibit the controller before disconnecting the plugs!

Advertising