2 brake connection, Electrical installation – Lenze MDxMA-MHxMA-MFxMA-MDERA-MHERA Three-phase AC motors User Manual

Page 35

Advertising
background image

Electrical installation

Wiring according to EMC

Brake connection

6

l

35

BA 33.0005−EN 2.0

Temperature monitoring

Terminal strip / terminal board

Meaning

Designation in accordance with EN 60034−8 Note

Thermal contact TCO

TB1

Max. 250 V~
Max. 1.6 A~

TB2

PTC thermistor

TP1
TP2

Thermal sensor +KTY R1

Observe polarity

Thermal sensor −KTY

R2

Terminal board or terminal possible for all thermal sensors

Blowers via blower terminal box / motor terminal box

External blower 3~

Terminal
board/terminal

Meaning

Note

U1

Connection to L1 − mains

Observe direction of rotation! In case of
incorrect rotation, interchange L1 − L2

V1

Connection to L2 − mains

W1

Connection to L3 − mains

External blower 1~

Terminal board /
terminal

Meaning

Note

U1

Connection to L1− mains

V1 / U2

Connection to N − mains

6.3.2

Brake connection

Terminal

Meaning

Add−on

~

AC−excited brake (rectifier)

Connection to L1 − mains

~

M

3~

Connection to N − mains

+

Brake connection

Brake connection

Switching contact, DC switching

BD1

Brake, DC operated

DC connection

BD2
MS1

Brake microswitch, release control

Two−way switch (black)

MS2

NC contact (brown)

MS4

NO contact (blue)

MS1

Brake microswitch, wear control

Two−way switch (black)

MS2

NC contact (blue)

MS4

NO contact (brown)

MS1

Brake microswitch, manual release

Two−way switch (black)

MS2

NC contact (blue)

MS4

NO contact (grey)

Advertising