1 motor plug connection assignment, 2 power connections, Feedback system – Lenze MDxMA-MHxMA-MFxMA-MDERA-MHERA Three-phase AC motors User Manual

Page 37: Plug connectors, Electrical installation

Advertising
background image

Electrical installation

Plug connectors

Motor plug connection assignment

6

l

37

BA 33.0005−EN 2.0

6.4.1

Motor plug connection assignment

)

Note!

When making your selection, the motor data and permissible currents of the
cables according to the system cable system manual must be observed.

6.4.2

Power connections

Power / brake / thermal sensor

ICN, 6−pole and 8−pole

6−pole (external view of poles)

Pin

Standard description

Meaning

M23

1
2

BD1 / BA1
BD2 / BA2

Brake + /

~

Brake − /

~

MT−Steckverbinder−001.iso/dms

+

PE

PE conductor

4
5
6

U
V
W

Power phase U
Power phase V
Power phase W

8−pole (external view of poles)

Pin

Standard description

Name

M23

1

U

Power phase U

MT−Steckverbinder−001.iso/dms

+

PE

PE conductor

3

W

Power phase W

4

V

Power phase V

A
B

TB1 / TP1 / R1
TB2 / TP2 / R2

Thermal sensor TCO /
PTC / + KTY
TCO / PTC / − KTY

C
D

BD1 / BA1
BD2 / BA2

Brake + /

~

Brake − /

~

8−pole (external view of poles) / connection variant ICN 8B

Pin

Standard description

Name

M23

1

U

Power phase U

MT−Steckverbinder−001.iso/dms

+

PE

PE conductor

3

W

Power phase W

4

V

Power phase V

A
B

TB1 / TP1 / R1
TB2 / TP2 / R2

Thermal sensor TCO /
PTC / + KTY
TCO / PTC / − KTY

C
D

BD1 / BA 1
BD2 / BA2

Rectifier: Switching
contact

Connection variant ICN 8B − switching contact of the rectifier for DC switching. Rectifier
supply via motor terminal board. Only possible during mains operation!

Advertising