2 electrical data, Electrical data, Technical data – Lenze E94AMHE User Manual

Page 57: 2 electrical data input data

Advertising
background image

Technical data

Electrical data

3

l

57

EDK94AMH24 DE/EN/FR/ES/IT 3.1

3.2

Electrical data

Input data

Basis of the data

Mains

Voltage

U

DC

[V]

Voltage range

U

DC

[V]

Frequency range

f [Hz]

2/PE DC

325

260 − 0 % ... 370 + 0 %

2/PE DC

565

455 − 0 % ... 620 + 0 %

2/PE DC

705

565 − 0 % ... 775 + 0 %

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C



max. +55 °C



E94AMxE0024

325/565/705

0 ( DC)

2.6/2.6/2.3

2.0/2.0/1.7

2

E94AMxE0034

325/565/705

0 ( DC)

4.3/4.3/3.8

3.2/3.2/2.9

2

E94AMxE0044

325/565/705

0 ( DC)

6.7/6.7/5.9

5.0/5.0/4.4

2

E94AMxE0074

325/565/705

0 ( DC)

12.1/12.1/10.6

9.1/9.1/8.0

2

E94AMxE0094

325/565/705

0 ( DC)

15.4/15.4/13.5

11.6/11.6/10.1

2

E94AMxE0134

325/565/705

0 ( DC)

20.6/20.6/18.0

15.5/15.5/13.5

2

E94AMxE0174

325/565/705

0 ( DC)

25.7/25.7/22.5

19.3/19.3/16.9

2

E94AMxE0244

325/565/705

0 ( DC)

35.5/35.5/31.1

26.3/26.3/23.3

2

E94AMxE0324

325/565/705

0 ( DC)

48.0/48.0/38.9

36.0/36.0/29.1

2

 Temperature in the control cabinet