Wiring the device modules, For the dip switches that are placed at the front, The node address (labelling "1" ... "64") and – Lenze E94AMHE User Manual

Page 77: Baud rate (labelling "a" ... "d") can be set

Advertising
background image

Wiring the device modules

Memory modules

8

l

77

EDK94AMH24 DE/EN/FR/ES/IT 3.1

SSP94M1001

Fig. 8−6

Memory module with DIP switch (as of order designation E94AYM22)

Baud

CAN Address

O

N

c

d

b

a

64

32

16

8

4

2

1

A

9400CAN003

Fig. 8−7

Arrangement and labelling of the DIP switches

For the DIP switches that are placed at the front

ƒ

the node address (labelling "1" ... "64") and

ƒ

baud rate (labelling "a" ... "d")

can be set.

)

Note!

If all address switches adopt the "OFF" position when the basic device is
switched on, the configurations of codes C00350 (nodes address) and C00351
(baud rate) apply.
Switch the voltage supply of the basic device off and then on again to activate
altered settings.

Setting the node address

The node address of the drive is calculated from the sum of all address switches in the "ON"
position.