EDK94AYAE DE/EN/FR/ES/IT 3.0

19

l

M5Lieferumfang−LED_An_Aus_Taktzeit

Displays

Pos.

Colour

State

Description

MS

(Module State)

Green

On

Drive−based safety has initialised without a fault.

Blinking

Drive−based safety has initialised without a fault.
Internal communication to the standard device is not
possible.

Flashing

Drive−based safety is in service status.
For exiting, parameterise the drive−based safety.

Off

Drive−based safety is not initialised.
Acknowledgement is not possible.

EN

(Enable)

Yellow

On

Controller enabled

Off

Non−safe display "STO"

ME

(Module Error)

Red

On

System error

Blinking

Trouble

Flashing

Warning

Off

Error−free operation

AS

(Acknowledge
Stop)

Yellow

On

Request of an acknowledgement for the restart or the
parameter set adoption

Blinking

SS1/STO active

Flashing

SS2/SOS active

Off

No stop function active

BE

(Bus Error)

Red

On

Safety bus error:

l

Communication is not possible.

l

Acknowledgement is possible.

Blinking

Safety bus error: no valid configuration.

Off

Safety bus: error−free operation.

DE

(Drive Error)

Red

On

Drive−based safety is not accepted by the standard
device (see notes in the instructions for the standard
device).

Off

Drive−based safety is correctly recognised by the
standard device.

Blinking: on/off every 0.5 s

Flashing: on/off every 0.1/0.9 s