2 technical data, 2technical data – Lenze E94AYAE SM301 User Manual
Page 28
Advertising
![background image](/manuals/565787/28/background.png)
2
Technical data
EDK94AYAE DE/EN/FR/ES/IT 3.0
28
l
H1_Daten−LESE SM301 HB SiFu
2
Technical data
24 V supply
The module and the safe output must be supplied with 24 V from safely separated power
supply units. To maintain electrical isolations, separate voltage supplies are required.
Detailed features of the 24−V supply
Terminal
Specification
[Unit]
min.
typ.
max.
+, −
Supply voltage of the module via a safely
separated power supply unit (SELV/PELV)
[V]
19.2
24
30
Input current
[mA]
350
24O, GO
Supply voltage of the safe output via a safely
separated power supply unit (SELV/PELV)
[V]
18
24
30
Input current
[mA]
1100
Safety functions
,
The manual for the safety module contains information on the safety
functions.
Advertising