Safety instructions

General safety information

EDK94AYAE DE/EN/FR/ES/IT 3.0

26

l

H1sic_EN−UL−Warn_Module_Temp_Fuse

Please observe the following safety instructions and application notes to preserve the
certified safety engineering features and to ensure trouble−free and safe operation.

}

Danger!

Danger to life through improper installation

Improper installation of the safety engineering systems can cause
anuncontrolled starting action of the drives.

Possible consequences:

ƒ

Death or severe injuries

Protective measures:

Total cable length between X82 and its connected components (e.g. sensors,
devices, ...) > 3 m:

ƒ

A shielded laying system must be used for the cable between X82 and its
connected components:
– The shield must at least cover the shield connection at the installation

backplane.

– The shield should also cover the connected component if possible.

ƒ

Unshielded wiring is permissible from hardware version 1A.

Total cable length between X82 and its connected components (e.g. sensors,
devices, ...) < 3 m:

ƒ

Unshielded wiring is permissible.

Residual hazards

In case of a short−circuit of two power transistors a residual movement of the motor of up
to 180 °/number of pole pairs may occur! (Example: 4−pole motor

Þ residual movement

max. 180 °/2 = 90 °)

This residual movement must be considered in the risk analysis, e.g. safe torque off for main
spindle drives.