Application range – Lenze E94AYAE SM301 User Manual

Page 22

Advertising
background image

EDK94AYAE DE/EN/FR/ES/IT 3.0

22

l

einsetzbarkeit−DUMMY_NUM_Reset

Application range

The use of this module is permissible with standard devices of the 9400 product series from
nameplate designation

Type

HW

SW

E94AxHExxxx

VA

01.49

E94AxPExxxx

2A

02.xx

Safe position and speed detection with a resolver as motor encoder and an additional
position encoder is permissible with SM301 V1.3 and standard devices of the 9400 product
series from nameplate designation

Type

HW

SW

E94AxHExxxx

xx

07.xx

E94AxPExxxx

2A

02.xx

Safe position and speed detection with a resolver as motor encoder is permissible with
SM301 V1.4 and standard devices of the 9400 product series from nameplate designation

Type

HW

SW

E94AxHExxxx

xx

08.xx

E94AxPExxxx

2A

02.xx

The use of this module is permissible with the PROFIBUS communication module from
nameplate designation

Type

HW

SW

E94AYCPM

VB

01.10

The use of this module is permissible with the PROFINET communication module from
nameplate designation

Type

HW

SW

E94AYCER

VC

00.70