4 safety module sm100, 1 overview, 2 safety category – Lenze E94AYAB − SM100 User Manual

Page 14: Safety module sm100, Safety engineering, Danger

Advertising
background image

Safety engineering

Device modules
Safety module SM100

1

l

14

EDS94AYAB EN 2.1

1.2.4

Safety module SM100

1.2.4.1

Overview

The type designation of the safety module is E94AYAB.

Function

ƒ

Safe torque off
(up to now: Safe standstill, protection against unexpected start−up)

}

Danger!

If the request for the safety function is cancelled, the drive will restart
automatically.
You must provide external measures which ensure that the drive only restarts
after a confirmation (EN 60204).

SM 100

SIA

SIB

GI

24O

DO1

GO

PWM

µC

-

~

-

-

SSP94S1010

Fig. 1−2

Function overview SM100

SM100

Safety module

SIA, SIB, GI

Two−channel sensor signal connections, supply through safely separated power
supply unit (SELV/PELV)
(old labelling up to HW version VB: SI1, SI2, GI)

24O, DO1, GO

Non−safe feedback connections, supply through safely separated power supply
unit (SELV/PELV)

mC

Microcontroller

PWM

Pulse width modulation

1.2.4.2

Safety category

The functions of the SM100 safety module for the Servo Drives 9400 controllers meet the
requirements of the following standards:

ƒ

Category 4 and Performance Level e (PL e) according to ISO 13849−1 (formerly
EN 954−1)
– In order to comply with category 4/PL e, the external wiring and cable monitoring

must also meet the requirements of category 4/PL e.

– Ensure that short circuits cannot occur in the external wiring.

ƒ

SIL 3 according to IEC 61508
– The SM100 safety module does not contribute to the probability of failure on

demand (PFD) and probability of failure per hour (PFH) of IEC 61508.

Advertising