3 elements of the module, 4 technical data, Safety engineering – Lenze E94AYAB − SM100 User Manual

Page 15

Advertising
background image

Safety engineering

Device modules

Safety module SM100

1

l

15

EDS94AYAB EN 2.1

1.2.4.3

Elements of the module

SSP94SM112

Fig. 1−3

Module view

Displays

Pos.

Colour

Condition

Description

EN

Yellow

On

Controller enabled

Off

Non−safe display "Safe pulse inhibit"

DE

Red

On

The module is not accepted by the standard device (see notes
given in the documentation for the standard device).

Tab. 1−1

LED display SM 100

1.2.4.4

Technical data

24 V

The inputs and outputs are isolated and designed for a low−voltage supply through a safely
separated power supply unit (SELV/PELV) of 24 V DC. P/N switching input signals and test
pulses

£ 1 ms are permissible.

Output signals of active sensors are directly wired to the X80 terminal.

Passive Sensors are wired to the X80 terminal via a switching device. The switching device
must comply with the required control category of the application.

There is no monitoring for short circuits.

Advertising