7 maintenance, 1 maintenance intervals, Maintenance – Lenze GPA servo planetary geared motors User Manual

Page 17: 7maintenance

Advertising
background image

Maintenance

Maintenance intervals

7



17

BA 12.0030 EN 2.0

7

Maintenance

Gearboxes and geared motors from Lenze are filled with a drive-specific and

design-specific lubricant filling at delivery. The mounting position and design are decisive

at ordering for the required lubricant quantity.

Note!

When changing the lubricant, Lenze recommends also changing the grease

packing of the bearings and replacing the radial shaft seal rings!

7.1

Maintenance intervals

ƒ The mechanical power transmission system is free of maintenance.
ƒ Shaft seals:

– The service life depends on the ambient conditions.
– Replace seals in case of leakage to avoid consequential damage.

ƒ Lubricating intervals:

– Gearboxes of type GPA are lubricated for life and hermetically sealed. In normal

operation, a lubricant change is not required.

– With extremely severe operation, we recommend changing the lubricant every

10,000 operating hours.

– The type of lubricant is indicated on the nameplate. Replace the lubricant only by

the same type.



Stop!

For drive systems: Also observe the maintenance intervals for the other drive

components!

Lubricants

Changing intervals

Type

Specification

Ambient

temperature

Note

g g

CLP PAO 150 Oil on synthetic basis

(polyglycol)

-20 °C...40 °C

Do not mix with

mineral oils!

10,000 operating hours, no longer

than three years

(oil temperature 70...100 °C)

Show/Hide Bookmarks