8 troubleshooting and fault elimination, Troubleshooting and fault elimination, Troubleshooting and fault elimination 8 – Lenze GPA servo planetary geared motors User Manual

Page 20: 8troubleshooting and fault elimination

Advertising
background image

Troubleshooting and fault elimination

8



20

BA 12.0030 EN 2.0

8

Troubleshooting and fault elimination

If any malfunctions should occur during operation of the drive system, please check the

possible causes using the following table. If the fault cannot be eliminated by one of the

listed measures, please contact the Lenze Service.

Fault

Possible cause

Remedy

Drive is at standstill

Voltage supply interrupted

Check connection

Wrong electrical connection

Check if nameplate matches voltage supply

Excessive load

Reduce load

Check drive - machine combination

Motor running, gearbox at

standstill

Fixing elements are missing or

defective

Check attachment

Gearbox is defective

Contact Lenze Service

Unusual noise

Overload

Reduce load

Check drive - machine combination

Damage in the gearbox or

motor

Contact Lenze Service

Excessive temperature

Overload

Reduce load

Check drive - machine combination

Insufficient heat dissipation

Improve cooling air supply

Clean gearbox / motor

Insufficient lubricant

Refill lubricant as specified

Loose fixing elements

Vibrations

Avoid vibrations