1 replacing the lubricant, Replacing the lubricant, Maintenance – Lenze GPA servo planetary geared motors User Manual

Page 18

Advertising
background image

Maintenance

Maintenance intervals

Replacing the lubricant

7



18

BA 12.0030 EN 2.0

7.1.1

Replacing the lubricant



Stop!

ƒ

Gearbox should be warm.

ƒ

Secure drive system and machine from inadvertent movement and mains

connection.

1. Drain lubricant by removing the oil drain/filler plug.
2. Fill recommended lubricant in the specified amount.
3. Insert oil drain/filler plug with new seal.
4. Dispose of waste oil according to applicable regulations.



Fig. 1

Position of oil filler/drain plug



Oil filler/drain plug

Recommended lubricant

Manufacturer

Mobil

Optimol

Type

Mobil SHC 629

Optigear Synthetic A 150

Show/Hide Bookmarks

Advertising