Technical data

General Data

EDK82ZAFPC-010 DE/EN/FR 6.0

48

H1_Daten-Schutzisolierung_010

4

Technical data

General Data

Field

Values

Order designation

E82ZAFPC010

PUO ID number

0x00DA

hex

Communication profile
(DIN 19245 part 1 and part 3)

PROFIBUS-DP

Communication medium

RS485

Drive profile

DRIVECOM profile ”Power Transmission 20”, can be switched off

Network topology

Without repeater: line
With repeater: line or tree

PROFIBUS node

Slave

Baud rate [kbps]

9.6 ... 12000 (automatic detection)

Process data words

1 word ... 10 words
(16 bits per word)

DP user data length

4 parameter data words +
1 ... 10 process data words

Max. number of nodes

Standard: 32 (= 1 bus segment)
With repeater: 125

Max. cable length per bus
segment

1000 m (depending on the baud rate and cable type used)

Communication time

Sum of the cycle time and the processing time in the fieldbus
nodes. The times are independent of each other.
Processing time in the controller:
– Parameter data: approx. 30 ms + 20 ms tolerance
– Process data: approx. 3 ms + 2 ms tolerance

External DC voltage supply

+24 V DC ±10 %, max. 80 mA