6electrical installation – Lenze E82ZAFPC010 User Manual
Page 60
Advertising
![background image](/manuals/565869/60/background.png)
6
Electrical installation
Voltage supply
EDK82ZAFPC-010 DE/EN/FR 6.0
60
H2_SpgVersorgg-Leg_Mindestverdraht
External voltage supply with two voltage sources for
1. X3.3/28 (controller inhibit (CINH))
2. X3.2/59 (function module)
GND1
GND1
B
7
20
59
+20V
A
28
39
7
GND2
_
_
+
+
X3.1
X3.2
X3.3
T/R(A)
T/R(B)
T/R(A)
T/R(B)
E82ZAFP013
The min. wiring requirements for operation