Installation – Lenze EMF2191IB User Manual
Page 31
Advertising
Installation
Electrical installation
Specification of the Ethernet cable
l
31
EDSMF2191IB EN 2.0
Colour code of Ethernet cable
)
Note!
Wiring and colour code are standardised in EIA/TIA 568A/568B.
You can use 4−pin Ethernet cables in accordance with the industrial standard.
The cable type only connects the assigned pins 1, 2, 3 and 6 with each other.
E94YCEI004A
Fig. 5−4
Ethernet plug in accordance with EIA/TIA 568A/568B
Pair
Pin
Signal
EIA/TIA 568A
EIA/TIA 568B
3
1
Tx +
White/green
White/orange
2
Tx −
Green
Orange
2
3
Rx +
White/orange
White/green
1
4
Not assigned
Blue
Blue
5
Not assigned
White/blue
Blue/white
2
6
Rx −
Orange
Green
4
7
Not assigned
White/brown
White/brown
8
Not assigned
Brown
Brown