2 setting the node address, Setting the node address, Commissioning – Lenze EMF2191IB User Manual

Page 35

Advertising
background image

Commissioning

Setting the node address

6

l

35

EDSMF2191IB EN 2.0

6.2

Setting the node address

)

Note!

ƒ

Use different node addresses for several networked inverters.
The Lenze setting for the node address (node ID) has the value ’4’:
– link switch in position ’0’
– right switch in position ’4’

ƒ

Switch the voltage supply of the inverter/communication module off and
on again to activate changed settings.

E94YCEP001D

Fig. 6−1

Setting the node address

Each node has to be assigned to a unique address (node ID).

ƒ

Valid address range for slave (controlled node): 1 ... 239

ƒ

The corresponding IP address of the communication module results from the setting
of the two rotary switches.
IP address: 192.168.100.<Node ID>

(Value

NJ

Left Switch

Nj

16))(Value

NJ

Right Switch

Nj

)

+ Node Address

Example

ƒ

Left rotary switch in position ’2’

ƒ

Right rotary switch in position ’5’

(2

16))5 + 37

==> The node address is ’37’.