Technical data, 4 p3 - controller i/o, Controller i/o – Lenze E94P v4.0 User Manual

Page 10

Advertising
background image

8

13433283_P94MI01D_EN

Technical Data

2.2.4

P3 - Controller I/O

Pin Name Function

CONTROLLER I/O

1

25

P3

50

26

50-pin SCSI connector

Pin

Name

Function

1

MA+

Master Encoder A+ / Step+ input

26

IN_A_COM

Digital input group A COM terminal

2

MA-

Master Encoder A- / Step- input

27

IN_A1

Digital input A1

3

MB+

Master Encoder B+ / Direction+ input

28

IN_A2

Digital input A2

4

MB-

Master Encoder B- / Direction- input

29

IN_A3

Digital input A3

5

GND

Drive Logic Common

30

IN_A4

Digital input A4

6

5+

+5V output (max 100mA)

31

IN_B_COM

Digital input group B COM terminal

7

BA+

Buffered Encoder Output: Channel A+

32

IN_B1

Digital input B1

8

BA-

Buffered Encoder Output: Channel A-

33

IN_B2

Digital input B2

9

BB+

Buffered Encoder Output: Channel B+

34

IN_B3

Digital input B3

10

BB-

Buffered Encoder Output: Channel B-

35

IN_B4

Digital input B4

11

BZ+

Buffered Encoder Output: Channel Z+

36

IN_C_COM

Digital input group C COM terminal

12

BZ-

Buffered Encoder Output: Channel Z-

37

IN_C1

Digital input C1

13

no connection

38

IN_C2

Digital input C2

14

no connection

39

IN_C3

Digital input C3

15

no connection

40

IN_C4

Digital input C4

16

no connection

41

RDY+

Ready output Collector

17

no connection

42

RDY-

Ready output Emitter

18

no connection

43

OUT1-C

Programmable output #1 Collector

19

no connection

44

OUT1-E

Programmable output #1 Emitter

20 AIN2+ Positive (+) of Analog signal input

45

OUT2-C

Programmable output #2 Collector

21 AIN2- Negative (-) of Analog signal input

46

OUT2-E

Programmable output #2 Emitter

22 ACOM Analog common

47

OUT3-C

Programmable output #3 Collector

23

AO

Analog output (max 10 mA)

48

OUT3-E

Programmable output #3 Emitter

24 AIN1+ Positive (+) of Analog signal input

49

OUT4-C

Programmable output #4 Collector

25 AIN1 - Negative (-) of Analog signal input

50

OUT4-E

Programmable output #4 Emitter

Digital Input A3
For the drive to function, an ENABLE input must be wired to the drive, and should be connected to IN_A3, (P3.29),
which is, by the default the ENABLE input on the drive. This triggering mechanism can either be a switch or an input
from an external PLC or motion controller. The input can be wired either sinking or sourcing. The Enable circuit will
accept 5-24V control voltage.

Digital and Analog I/O Ratings

I/O

Scan Times Linearity Temperature Drift

Offset

Current

Input Impedance Voltage Range

Units

ms

%

%

%

mA

Ohm

VDC

Digital Inputs

(1)

512

Depend on

load

2.4 k

5-24

Digital Outputs

512

100 max

N/A

30 max

Analog Inputs

512

± 0.013 0.1% per °C rise

± 0

adjustable

Depend on

load

47 k

± 10

Analog Outputs

512

0.1% per °C rise

± 0

adjustable

10 max

N/A

± 10

(1)

Inputs do not have scan time. Their values are read directly by indexer program statement.
De-bounce time is programmable and can be set as low as 0. Propagation delay is typically 20 us