Lenze ECSCExxx User Manual

Page 64

Advertising
background image

Safety instructions

Residual hazards

1

l

64

EDKCSCE040 DE/EN/FR 3.0

Device protection

ƒ

The power supply module may only be driven from balanced mains
supplies. Mains supplies with earthed phase are not permitted.

ƒ

The power supply module contains electrostatic sensitive devices. The
personnel must be free of electrostatic charge prior to assembly and
service operations.

ƒ

All pluggable connection terminals must only be connected or
disconnected when no voltage is applied!

ƒ

The power terminals +UG, −UG and PE are not protected against polarity
reversal.

When wiring, observe the polarity of the power terminals!

ƒ

Observe the max. permissible mains voltage. Higher voltages will damage
the power supply module.

ƒ

Operation is not permitted

without the use of a brake resistor.

if an internal brake resistor and an external brake resistor are used
simultaneously.

if several power supply modules are connected in parallel.

Advertising