I/o details – Lenze SS208AC User Manual

Page 19

Advertising
background image

SimpleServo 100/200 User Manual Rev 3.4

I/O DETAILS

1. Step and Direction/ Master Encoder Inputs: TB2-12,13,14,15

You can connect a master encoder with quadrature outputs or a step and direction to control position in

step/direction operating mode. You can connect a single ended or differential TTL or CMOS compatible

5V sourcing signals to the inputs. You can also connect sink open collector outputs to these inputs. See

application note in "Section A" of this manual for the connection guidelines. The function of these inputs

"Master Encoder" or "Step and Direction" is software selectable. Use MotionView set up program to

choose desirable function.

WARNING!

Inputs compatible only with 5V logic or open collector outputs. Higher voltages will

damage drive's circuit.

1K

R9

1K

R4

C5

180pF

R5

20K

R10

20K

STEP- (TB2-13)

VC

C

GN

D

ENABLE
ENABLE

OUTA

OUTC

OUTB

OUTD

-INA
+INA

+INB
-INC
+INC
-IND
+IND

-INB

16

8

4

12

3

5

11

13

1
2

14

6
7
9

10

15

DS26LS32AC

U1

STEP+ (TB2-12)

DIRECTION- (TB2-15)

1K

R2

DIRECTION+ (TB2-14)

To drive's

1K

R7

R8

20K

C4
180pF

C1
180pF

+5V

R3

20K

R6

5.11K

R1

5.11K

C6

180pF

Master encoder/step and direction input circuit. (SS208 drives only)

19

Advertising
This manual is related to the following products: