Electrical installation
Supply voltage connection
4
l
65
EDBPM−H502 DE/EN/FR 5.1
4
Electrical installation
(
Stop!
ƒ
Damage of units connected. Connect the PE conductor as shown
in the figure!
ƒ
Wire the operating unit only when no voltage is applied!
4.1
Supply voltage connection
FUSE 800 mA
+(18-32) VDC 10W
0 VDC
1
2
3
4
N. C.
~
PE
N
L1
+18…32VDC
12
3
4
ASP8
N.C.
CAN+
Shield
CAN-
V-
1 2 3 4 5
h502_006
Fig. 4−1
Supply voltage connection
Terminal assignment
Terminal
Identification
Explanation
1
+24 VDC
Supply voltage (DC +18 V ... 32 V)
2
0 VDC
GND supply voltage, reference potential
3
n.c.
Not connected
4
PE potential