RG-TFMOD 16
Drive Control & Communication
5.4.7 Present Fault - Registers #24 & 29
Table 15 lists the Present Fault (Register #24 byte D6H of Register #29 DH)
Table 15: Present Fault
Setting
Fault
Display
0
NO FAULT
1
TEMPORARY OUTPUT FAULT
2
OUTPUT (TRANSISTOR) FAULT
“OF”
3
HIGH DRIVE TEMPERATURE
“AF”
4
FLYING RESTART FAULT
“Rf”
5
HIGH DC BUS VOLTAGE
“HF”
6
LOW DC BUS VOLTAGE
“LF”
7
THERMAL OVERLOAD
“PF”
8
OEM FAULT
“GF”
9
ILLEGAL SETUP
“IL”
10
DYNAMIC BRAKE OVERHEATED
“dF”
11
SINGLE PHASE FAULT
“SF”
12
EXTERNAL
“EF”
13
CONTROL FAULT
“CF”
14
START ERROR
“UF”
15
INCOMPATIBILITY FAULT
“cF”
16
INTERNAL1 (EPM)
“F1”
17
INTERNAL2
“F2”
18
INTERNAL3
“F3”
19
INTERNAL4
“F4”
20
INTERNAL5
“F5”
21
INTERNAL6
“F6”
22
INTERNAL7
“F7”
23
INTERNAL8
“F8”
24
INTERNAL9
“F9”
25
PERSONALITY FAULT
“bF”
26
A/D OFFSET FAULT
“Ad”
27
SERIAL LINK FAULT
“JF”
28
ASSERTION LEVEL CHANGED FAULT
“AL”
29
USER ASSERTION LEVEL FAULT
“A1”
30
OEM ASSERTION LEVEL MIS-MATCH FAULT
“A2”
31
EEPROM CHECKSUM FAULT
“A3”
32
ASSERTION LEVEL HARDWARE FAULT
“A4”