Drive control & communication – Lenze TCF Series Drives Modbus Communications User Manual

Page 20

Advertising
background image

RG-TFMOD 16

Drive Control & Communication

5.4.7 Present Fault - Registers #24 & 29

Table 15 lists the Present Fault (Register #24 byte D6H of Register #29 DH)

Table 15: Present Fault

Setting

Fault

Display

0

NO FAULT

1

TEMPORARY OUTPUT FAULT

2

OUTPUT (TRANSISTOR) FAULT

“OF”

3

HIGH DRIVE TEMPERATURE

“AF”

4

FLYING RESTART FAULT

“Rf”

5

HIGH DC BUS VOLTAGE

“HF”

6

LOW DC BUS VOLTAGE

“LF”

7

THERMAL OVERLOAD

“PF”

8

OEM FAULT

“GF”

9

ILLEGAL SETUP

“IL”

10

DYNAMIC BRAKE OVERHEATED

“dF”

11

SINGLE PHASE FAULT

“SF”

12

EXTERNAL

“EF”

13

CONTROL FAULT

“CF”

14

START ERROR

“UF”

15

INCOMPATIBILITY FAULT

“cF”

16

INTERNAL1 (EPM)

“F1”

17

INTERNAL2

“F2”

18

INTERNAL3

“F3”

19

INTERNAL4

“F4”

20

INTERNAL5

“F5”

21

INTERNAL6

“F6”

22

INTERNAL7

“F7”

23

INTERNAL8

“F8”

24

INTERNAL9

“F9”

25

PERSONALITY FAULT

“bF”

26

A/D OFFSET FAULT

“Ad”

27

SERIAL LINK FAULT

“JF”

28

ASSERTION LEVEL CHANGED FAULT

“AL”

29

USER ASSERTION LEVEL FAULT

“A1”

30

OEM ASSERTION LEVEL MIS-MATCH FAULT

“A2”

31

EEPROM CHECKSUM FAULT

“A3”

32

ASSERTION LEVEL HARDWARE FAULT

“A4”

Advertising