Drive control & communication – Lenze TCF Series Drives Modbus Communications User Manual

Page 29

Advertising
background image

25 RG-TFMOD

Drive Control & Communication

NOTE 5 - AC Tech Register #101, Parameter 51 - Software Version
When parameter #101 is read, the number of registers can be either 1 or 4. In case of 4
register read, the drive will send 8 bytes of data back to the MASTER. It does not mean
the read function reads parameter #101, #102, #103, and #104. This is a special case to
handle the ASCII string representing software version. The ASCII string may look like this:
“ TF12801”. In case of reading one register, received high byte contains software version
and low byte revision number. If received word contains hexadecimal number 0x8001 it
translates to:

0x80 --> decimal 128 (software version) and
0x01 --> decimal 1 (revision number).

NOTE 6 - AC Tech Registers 107 & 108 - Digital I/O
Table 18 lists the format of AC Tech Register #107, Parameter 57 - TB Strip Status.
Table 19 lists the format of AC Tech Register #108, Parameter 58 - Keypad Status.

Table 18

Table 19

AC Tech Register #107

AC Tech Register #108

TB Terminal Strip Status

Keypad Status

Data Low Byte

0

Not used

Data Low Byte

0

Not used

1

Not used

1

Not used

2

Protect (pin FAULT3)

2

Not used

3

FCLIM (pin FAULT4)

3

UP PB

4

STOP

4

DOWN PB

5

Not used

5

PROG PB

6

TB13A

6

Not used

7

TB13B

7

FAST CLIM

Data High Byte

8

TB13C

Data High Byte

8

PROTECTION

9

Open Collector TB14

9

Not used

10

Open Collector TB15

10

Not used

11

Charge Relay

11

Not used

12

TB13D

12

Not used

13

Not used

13

Not used

14

Not used

14

Not used

15

Not used

15

Not used

NOTE - AC Tech Registers #134 & 142
Register #134, Parameter 84 (Stator Resistance) and Register #142, Parameter 92 (Motor
Inductance) are automatically adjusted when the Auto Calibration function (Parameter 81)
is performed. Once the Auto Calibration is complete, the settings should not change.