Lenze E94AxHE Technology Application Positioning sequence control User Manual
Page 18

9400 Technology applications | Positioning sequence control
Short setup
Step 2: Parameterising the application
18
L
EDS94TA10060xxxx EN 1.2 - 03/2010
Setting the machine parameters
1. Set the selection "mm" as unit (C02525).
– This parameter is used to define the real unit of the machine for the selection of
physical values (e. g. speeds, accelerations and decelerations).
2. Set feed constant (C02524).
– The feed constant corresponds to the motion of the machine at one revolution of the
gearbox output shaft.
– For the sheet stacker: Feed constant = 250 mm/rev.
3. Click Back to go back to the Overview dialog level.
4. In the Overview dialog level, click Program flow to change to the dialog level Overview
Program flow and select the positioning program.
Go to dialog:
Overview
Machine parameter