9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Parameterisable function blocks
5.14.14
PosStarted
5.14.15
RestartPosTransition
Is an instance of
Function
L_TbTransition
Edge generation for resetting the "drive at the target" state
Parameter
Possible settings
Information
C04000
Trigger edge
0 Rising edge
Lenze setting
1 Falling edge
2 Both edges
C04001
0.001
s
60.000 Pulse duration
• Initialisation: 0.001 s
Is an instance of
Function
L_TbTransition
Edge generation for restart of positioning
Parameter
Possible settings
Information
C04002
Trigger edge
0 Rising edge
Lenze setting
1 Falling edge
2 Both edges
C04003
0.001
s
60.000 Pulse duration
• Initialisation: 0.005 s