9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Following error monitoring
54
L
EDS94TA10060xxxx EN 1.2 - 03/2010
5.6
Following error monitoring
[5-12] Following error monitoring
Parameter setting: Tab Application parameters dialog level Overview Following
error
n
Switching threshold
o
Hysteresis
In the Lenze setting a two-stage following error monitoring is
active.
If the parameterisable switching threshold 1 is exceeded, a
warning appears. If the higher-set switching threshold 2 is
exceeded, a "warning locked" appears.
j
Parameter
Lenze setting
Value Unit
C03911
Switching threshold 1
100.0000 unit
C03914
Switching threshold 2
200.0000 unit
C03917
Hysteresis 1
0.0000 unit
C03920
Hysteresis 2
0.0000 unit
C05902/1
Error response - following error 1
Warning
C05902/2
Error response - following error 2
Warning locked
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
TRUE Activate following error limit 1
C03058/1
TRUE Activate following error limit 2