9400 Technology applications | Positioning sequence control
Short setup
Step 3: Parameterising the program flow
22
L
EDS94TA10060xxxx EN 1.2 - 03/2010
4.6.4
Program step 4: Counting the sheets
4.6.5
Program step 5: Setting the status output
Tip!
In a later step, sequence control output 1 will be connected with digital output
DO3.
Action
Comment
Parameter Setting
Count the sheets and go back to program step 3,
unless 10 sheets are reached.
Selection Action Number: 1
Counter no.: 1
Comparison function: Count <
comparison
value
Step value: 1
Comparison value: 10
Sequence step: 3
1
3
4
2
Action
Comment
Parameter Setting
Set sequence control output 1 to "1", when
maximum number of sheets (10) is reached.
Selection Action Number: 1
Output for A switching: Output 1
Signal state for A switching:
Output for B switching: Deactivated
Signal state for B switching: