Lenze E94AxHE Technology Application Positioning sequence control User Manual
Page 58

9400 Technology applications | Positioning sequence control
Parameter setting & configuration
Limiter
58
L
EDS94TA10060xxxx EN 1.2 - 03/2010
For manual jog only
C02713
Max. manual jog distance
360.0000 unit
Limited speed 1 ... 4 (only for homing, positioning, and manual jog)
C02708/1
Limited speed 1
3600.0000 unit/s
C02710/1
Delay lim. speed 1
0.0100 unit/s
2
C02711/1
S-ramp time lim. speed 1
100 ms
C02708/2
Limited speed 2
7200.0000 unit/s
C02710/2
Delay lim. speed 2
0.0100 unit/s
2
C02711/2
S-ramp time lim. speed 2
100 ms
C02708/3
Limited speed 3
14400.0000 unit/s
C02710/3
Delay lim. speed 3
0.0100 unit/s
2
C02711/3
S-ramp time lim. speed 3
100 ms
C02708/4
Limited speed 4
28800.0000 unit/s
C02710/4
Delay lim. speed 4
0.0100 unit/s
2
C02711/4
S-ramp time lim. speed 4
100 ms
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
DIGIN 3 Positive limit switch
C03150/1
DIGIN 4 Negative limit switch
C03150/2
Parameter
Lenze setting
Value Unit