MAINTENANCE AND TROUBLESHOOTING

°

4. Blade Stops Turning:






































































* A GFCI wall socket is the preferred protective device.

(D)

Verify the circuit breaker is at least

20 amps – if not, move to

a 20-amp circuit

(A)

Allow the motor to cool and

depress motor Overload

Reset Switch

(F)

Check power source voltage is

115V, if it is not 115v –

move to another circuit

(B)

Verify all plugs are fully

installed*

(C)

Check to see if the Ground

Fault Circuit Interrupter (GFCI)

is tripped*

(E)

Verify circuit breaker is not tripped,

if it is tripped – reset the

circuit breaker once

Return to

MK Diamond

for Repair

(G)

Return to MK Diamond


If less than 20

Amps, move saw

to 20 Amp circuit

Overload

Reset Switch

If motor does not

start, go to Step B

Verify all plugs

are connected

If all plugs are connected,

go to Step C

If not tripped, or

If a re-trip occurs,

go to Step D

Reset once

if tripped

If circuit is 20

Amps or greater,

go to Step E

Check Breaker

20 Amps

or greater

If tripped, reset

once, if it trips again,

go to step F

If circuit breaker

not tripped,

go to Step F

Check Breaker

tripped

If circuit breaker

is not tripped,

go to Step F

Check for

correct circuit

voltage