Notice, Caution, Warning – MK Diamond MK-1080 User Manual

Page 9

Advertising
background image

9

To choose the proper extension cord:

ELECTRIC MOTOR SAFETY

For maintenance care and operation of the electric motor, refer to your electric motor instruction booklet

furnished with the electric motor. Protect the electric motor from dust as much as possible and keep

ventilating openings clean.

• DO NOT spray water on the electric motor. Do not touch the plug with wet hands. To

reduce the risk of electrocution, keep all connections dry and off the ground.
• DO NOT operate electric motor in an explosive environment.

CAUTION

MK-1080 PAVER SAW

SAFETY

NOTICE

Most Motor Problems are caused by improper
voltage and extension cords. Cord should be
one-piece and short as possible. Cord
selection should match the following table.

1-2 H.P.

25’
50’
75’

100’

150’

250’

Max. Cord Length
Max. Cord Length
Max. Cord Length

No. 12 Wire
No. 10 Wire
No. 8 Wire

115v 230v

Fig. 1 Extension Cord Table

WARNING

Use only extensions cords that are intended for outdoor use. These extension cords are identified

by a marking, “Acceptable for use with outdoor appliances; store indoors while not in use.” Use only

extension cords having an electrical rating not less than the rating of the product. Do not use dam-

aged extension cords. Examine extension cords before using and replace if damaged. Do not abuse

extension cords and do not yank on any cord to disconnect. Always disconnect the extension cord

from the receptacle before disconnecting the product from the extension cord.

WARNING

• Locate the length of extension cord needed

in

table to the right.

• Once the proper length is found, move

down the column to obtain the correct

AWG size required for that length of

extension cord.

Use of undersize extension cords result in low voltage to the motor that can result in motor burnout

and premature failure. MK Diamond warns that equipment returned to us showing signs of being run

in a low voltage condition, through the use of undersized extension cords will be repaired or replaced

totally at the customers expense. There will be no warranty claim.

Electric Motor Connection

ALWAYS make certain that the power source required for the electric motor is correct and always

use the correct NEMA configuration plug. Motors can burn out when the line voltage falls 10% below

the voltage rating of the motor. Failure to use proper voltage will cause the motor to overheat. Make

certain that the correct size grounded (3-wires) extension cord is used. See the table below.