(A)

Remove the front tower panel to ob-

tain access to the battery terminals.

(A)

Check the oil level on the expansion

tank to ensure that the transmission

has adequate fluid.

(B)

Connect the positive (+) battery

cable to the positive battery terminal.

Connect the negative battery cable

to the negative terminal. Tighten

the cap screws and nuts securely

to assure proper electrical contact.

Replace panel.

MK-20 SERIES ASSEMBLY

BATTERY PREPARATION

HYDRO-STATIC TRANSMISSION

The 12 volt battery is shipped wet and charged. Connect the battery leads according to the following

steps to ensure that power is provided to the engines electric starter.

The Hydro-Static Transmission is factory filled with fluid having a viscosity equivalent to SAE 20 W

20.

Do not overfill the expansion tank. Notice that the full level line is near the

bottom of the expansion tank. Over filling will result in rupturing the seals

on the hydromatic transmission and subsequent mechanical damage.

When tightening the positive (+) battery cable end, do not contact the nega-

tive (-) battery terminal with the wrench or other metallic objects. This could

cause an electrical short and electrical sparking or an explosion of the battery.

Be careful not to connect the battery in reverse polarity, as this will short circuit

the battery charging system causing the fuse on the engine to become dam-

aged, and also possibly resulting in an explosion of the battery.

NOTICE

WARNING