Test System Modes of Operation

There are four operating modes for this test system:

Hydraulic Power Off

Specimen Installation and Setup

Run mode

Service

Hydraulic power off

Hydraulic Power is prevented from energizing the circuit via the hydraulic
service manifold. Full access to the test area is allowed in this mode.

Specimen installation

and setup

The controller provides a means for creating a specimen installation mode. This
mode typically uses the Channel Limited Channel (CLC) control method. The
primary control channel is Displacement (stroke) with maximum limits set on
applied force. Tuning parameters unique to this mode optimize manual control
during this mode. In addition, a maximum velocity command is set.

The handset has the ability to have a configuration specific desired response to
the thumbwheel encoder on the handset for a precise level of control.

In conjunction with the controller and specimen installation mode using the
handset, the load frame itself has two operation modes, full flow, and actuator
velocity limiting restricted flow. A switch on the load frame control panel
activates a solenoid which controls a hydraulic circuit within the load frame
hydraulic service manifold. In the actuator velocity limiting mode, oil flow to the
actuator is directed through an orifice which limits actuator velocity to 10 mm/
second or less.

7

Connector

RJ-45, to Controller.

8

Hydraulic off

Shuts down the HPU.

9

Start

Starts the test action. Only if the application test software is
active.

10

Interlock reset

Resets active interlock(s) providing the cause for the
interlock(s) has been remedied.

11

Thumbwheel enable

Press to enable the thumbwheel to position the actuator. Press
again to disable the thumbwheel, Indicator lights when
thumbwheel is active.

12

Fault

Indicator. When lit, indicates an active fault or interlock.

13

Handset enable

Used to enable/disable the handset. When the indicator is lit,
the handset is enabled for control of the actuator.

14

Select (Enter)

Selects the highlighted line in the display.

15

Display

Four lines, 20 characters per line.

Handset Controls and Indicators

#

Control/Indicator

Description

Advertising