Effects of Controller Actions
Actuator
Command Signal
Power
Test State
Action
Selected
Unaffected by the
tripped limit
Unaffected by the
tripped limit
Unchanged
Run
No Action
Unaffected by the
tripped limit
Unaffected by the
tripped limit
Unchanged
Run
Indicate
Holds at the current
position of the
Command signal
Holds at the location
where the limit tripped
Off
Stop
Station Power
Off
Holds at the current
position of the
Command signal
Holds at the location
where the limit tripped
Off
Stop
Interlock
Holds at the current
position of the
Command signal
Holds at the location
where the limit tripped
Unchanged
Stop
Program Stop
Interlock
Holds at the current
position of the
Command signal
Holds at the location
where the limit tripped
Unchanged
Hold
Program Hold
Interlock
Holds at the current
position of the
Command signal
Holds at the location
where the limit tripped
Unchanged
Stop
C-Stop
Interlock
Holds at the current
position of the
Command signal
Holds at the location
where the limit tripped
Unchanged
Stop
Program Stop
Holds at the current
position of the
Command signal
Holds at the location
where the limit tripped
Unchanged
Hold
Program Hold
422 | MTS TestSuite
Test Activities