MTS SWIFT 20 Ultra Sensor User Manual

Page 56

Advertising
background image

SWIFT 20 Sensors

56

TISETZERO – Low-Profile Transducer Interface Set

Software Utilities

TISETZERO – Low-Profile Transducer Interface Set
Zero Method

This program allows some configuration settings to be changed in a SWIFT
Low-Profile Transducer Interface (TI) without modifying a settings file. This
program only changes configuration settings, it does not change any calibration
settings.

Syntax

:

tisetzero port box [zero_algo]

port is the communications

1 = COM1:
2 = COM2:

box is the Low-Profile TI communications address

1 = lowest possible address
9 = highest possible address

zero_algo is optional and specifies the zero algorithm

0 = lowest
4 = highest

Example

Option 0

Use this option to exit the program

Option 1

Use this option for fixed (non-spinning) applications. It sets the AngleMode to 1
(fixed) and the ZeroAlgorithm to 0 (fixed). You may need to set the fixed angle
manually.

Option 2

Use this option for spinning applications. It sets the AngleMode to 0 (encoder)
and the ZeroAlgorithm to 1 (spinning bridge, angle with level).

Option 3

Use this option for spinning applications. It sets the AngleMode to 0 (encoder)
and the ZeroAlgorithm to 3 (spinning bridge and angle)

Option 4

Use this option for spinning applications. It sets the AngleMode to 0 (encoder)
and the ZeroAlgorithm to 4 (2-point bridge and angle with level).

C:\bin>tisetzero 1 1

Firmware Version: 2.6.1

Current angle mode is ENCODER

Current zero algorithm is SPINNING BRIDGE AND ANGLE UNLOADED

Zero algorithms...

0) exit

1) fixed

2) spinning bridge

3) spinning bridge and angle unloaded

4) spinning 2 point

Enter choice?

Advertising