Test track vehicle for slip ring sensor, Test track vehicle for slip ring sensor 74 – MTS SWIFT 20 Ultra Sensor User Manual

Page 74

Advertising
background image

SWIFT 20 Sensors

74

Test Track Vehicle for Slip Ring Sensor

Installing the Transducer

Test Track Vehicle for Slip Ring Sensor

Equipment required

This procedure requires one person. To install the SWIFT 20A or SWIFT 20T
slip ring sensor, you will need the following equipment:

Hub adapter (see next figure)

Modified rim (see next figure)

Anti-rotate assembly (including customer-supplied mounting arm)

Small set of hex-head wrenches (both English and metric)

Tube bender for the anti-rotate bar

Tube cutter

Metric socket head drive set (up to 14 mm) with extension

5/16-18 UNC tap

Molykote g-n paste (MTS part number 011-010-207)

Bolts

For SWIFT 20A Transducer

40 size M8 X 1.25 mm

8 size M5 X 0.8 mm

lug nuts

For SWIFT 20T Transducer

32 size M10 X 1.5 mm

12 size M8 X 1.25 mm

8 size M5 X 0.8 mm

Lug nuts

Torque wrenches, capable of the following ranges:

14–28 N•m (10–20 lbf•ft);

28–54 N•m (20–40 lbf•ft),

81–136 N•m (60-100 lbf•ft);

7 N•m (60 lbf •in)

Cables (transducer and BNC, plus customer-supplied from transducer
interface to data recorder). If the SWIFT is designed to operate with the
Low-Profile TI and you have a Mini TI, you will need an adapter cable,
MTS part number 100224052.

Tie wraps

Data recorder

Advertising