Run Mode
The system is fully operational when all of the following have been satisfied.
•
The test area enclosure doors are closed.
•
The actuator velocity limiting is in full-flow state.
•
The handset and manual control are yielded to controller.
•
The system is in high pressure.
Service
Most normal service requirements can be met utilizing the normal three operating modes as listed previously.
However, there can be circumstances where operation in full flow mode with the test area enclosure open is
required. In these cases, trained service personnel can disconnect the standard enclosure cable, and
temporarily replace it with a service connector. This operation is not considered typical use, and should only
be used by trained individuals.
Emergency Stop and Actuator Velocity Limiting Switch
The emergency stop switch and actuator velocity limiting switch function the same as those on the control
panel.
Enclosure Controls
Description
Item
Emergency Stop Switch
1
Actuator Velocity Limiting Switch
2