Cable assemblies, Low loss flexible cable 6/50 d, Low loss flexible cable 5/50 d – Northern Connectors Radiall RF & Microwave Cable Assemblies User Manual

Page 19: Eco230), Lmr200 type), Construction / dimensions, Electrical characteristics, Mechanical characteristics, Environmental characteristics

Advertising
background image

www.radiall.com

B-20

Cable assemblies

lOW lOSS flEXIblE

CablE 6/50 D

(ECO230)

p/N: C291 326 490

Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

OFC

(1)

copper

1.46

0.057

dielectric

foam PE

(2)

4.07

0.160

inner shield

Al

(3)

foil

4.27

0.168

outer shield

TC

(4)

braid

4.75

0.187

jacket

black LSZH

(5)

PE

5.90

0.232

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 2Ω

operating frequency range

DC - 4 GHz

shielding effectiveness

90 dB (DC - 3 GHz)

voltage withstanding

3 000 V rms

peak power

3.3 kW

capacitance

84 pF / m

25.5 pF / ft

velocity of propagation

79 % (4.2 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

25 mm

0.98 inch

weight

62 g / m

0.0417 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +85 °C

-40 / +185 °F

fire resistance

yes (UL1581 VW1 / IEC 332-1)

halogen free

yes (IEC 754-2)

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 40 °C)

GHz

dB / m

dB / ft

Watts

0.2

0.12

0.04

391

0.4

0.17

0.05

277

0.6

0.21

0.06

226

0.8

0.25

0.08

196

1.0

0.28

0.08

175

1.5

0.35

0.10

143

2.0

0.40

0.12

124

2.5

0.45

0.14

111

3.0

0.50

0.15

101

4.0

0.59

0.18

88

attenuation calculation (dB/m)

(0.264 x √f GHz) + (0.015 x f GHz)

power calculation (W)

175 / √f GHz

(1)

OFC = Oxygen Free Copper

(2)

PE = PolyEthylene

(3)

Al = Aluminum

(4)

TC = Tinned Copper

(5)

LSZH PE = Low Smoke Zero Halogen PolyEthylene

Designed by RADIALL, ECO230 is an
advantageous alternative solution to 5 mm dia.
cables when higher power level is required:

• Advantageous in term of electrical
performance:

its optimized construction allows

better attenuation and screening effectiveness
than RG cables.

• Advantageous in term of environmental
aspect:

halogen and sulphur free, this cable

does not emit any toxic substance when
submitted to fire.
The flame retardant jacket allows ECO230 to
meet fire resistance standards.

• Advantageous in term of price:

ECO230

design has integrated all RADIALL knowledge
to reach the best performances with a very
competitive price.

ECO230 is UL style 1375 approved.

APPLICATION NOTE

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

solid copper

1.12

0.044

dielectric

foam PE

(1)

2.95

0.116

inner shield

Al

(2)

foil

3.07

0.121

outer shield

TC

(3)

braid

3.66

0.144

jacket

black PE

(1)

4.95

0.195

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 2Ω

cut-off frequency

39 GHz

recommend. operat. freq. range

DC - 6 GHz

shielding effectiveness

> 90 dB

voltage withstanding

1 000 V DC

peak power

2.5 kW

capacitance

80.3 pF / m

24.5 pF / ft

velocity of propagation

83 % (4.0 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

12.7 mm

0.50 inch

weight

30 g / m

0.022 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +85 °C

-40 / +185 °F

fire resistance

no

halogen free

no

fREqUENCy / aTTENUaTION (typ.) /

CW Typ pOWER (sea level / 40 °C)

GHz

dB / m

dB / ft

Watts

0.1

0.11

0.03

560

0.5

0.24

0.07

240

1.0

0.34

0.10

170

1.5

0.42

0.13

140

2.0

0.49

0.15

120

2.5

0.55

0.17

110

3.0

0.61

0.18

100

4.0

0.71

0.22

80

5.0

0.80

0.24

70

6.0

0.88

0.27

65

attenuation calculation (dB/m)

(0.333 x √f GHz) + (0.011 x f GHz)

(1)

PE = PolyEthylene

(2)

Al = Aluminum

(3)

TC = Tinned Copper

This LMR200 type cable can be considered
as an alternative to equivalent diameter
corrugated cables.
The main advantage is greater flexibility and
bendability allowing easy routing during the
installation.
The foam dielectric provides excellent loss
and low return loss levels.
The double screen construction (Aluminum
foil + tinned copper braid) offers a high level
of shielding as well as low leakage.
This cable will be advised for feeder and
jumper assemblies in cellular networks as
well as applications requiring easy routing.

APPLICATION NOTE

lOW lOSS flEXIblE

CablE 5/50 D

(LMR200 type)

p/N: C291 316 070

Advertising