Cable assemblies, Flexible cable 6/75 s, Rg59) – Northern Connectors Radiall RF & Microwave Cable Assemblies User Manual

Page 20: Kx6a), Construction / dimensions, Electrical characteristics, Mechanical characteristics, Environmental characteristics

Advertising
background image

www.radiall.com

B-21

: Service+ program = fast delivery

Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)

Cable assemblies

Due to its 75 ohms characteristic impedance,
RG59 is rather dedicated to TV/Video
application.

Its solid inner conductor allows better
attenuation than the equivalent KX solution
(KX6).

APPLICATION NOTE

flEXIblE CablE 6/75 S

(RG59)

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

solid CCS

(1)

0.57

0.022

dielectric

solid PE

(2)

3.71

0.146

inner shield

copper braid

4.50

0.177

outer shield

-

-

-

jacket

black PVC

(3)

6.15

0.242

ElECTRICal ChaRaCTERISTICS

characteristic impedance

75Ω ± 3Ω

operating frequency range

DC - 1 GHz

shielding effectiveness

40 dB

voltage withstanding

7 000 V rms

peak power

2.7 kW

capacitance

60 pF / m

18.2 pF / ft

velocity of propagation

66 % (5 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

30 mm

1.18 inch

weight

47 g / m

0.0315 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +85 °C

-40 / +185 °F

fire resistance

no

halogen free

no

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

0.05

0.09

0.03

335

0.1

0.13

0.04

237

0.2

0.19

0.06

168

0.3

0.23

0.07

137

0.5

0.30

0.09

106

0.6

0.33

0.10

97

0.7

0.36

0.11

90

0.8

0.39

0.12

84

1.0

0.44

0.13

75

attenuation calculation (dB/m)

(0.40 x √f GHz) + (0.04 x f GHz)

power calculation (W)

75 / √f GHz

(1)

CCS = Copper Covered Steel

(2)

PE = PolyEthylene

(3)

PVC = PolyVinyl Chloride

p/N: C291 360 000

(MIL-C-17/29-RG59)

Relevant standard: NF-C-93/550-KX6 (France)

Due to its stranded inner conductor, KX6 is
much more flexible than RG59.

This cable will be chosen instead of RG59 for
specific applications requiring high flexibility.

APPLICATION NOTE

flEXIblE CablE 6/75 S

(KX6A)

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

stranded copper

0.60

0.024

dielectric

solid PE

(1)

3.70

0.146

inner shield

copper braid

4.50

0.177

outer shield

-

-

-

jacket

green PVC

(2)

6.10

0.240

ElECTRICal ChaRaCTERISTICS

characteristic impedance

75Ω ± 3Ω

operating frequency range

DC - 1 GHz

shielding effectiveness

40 dB

voltage withstanding

7 000 V rms

peak power

2.7 kW

capacitance

63 pF / m

19 pF / ft

velocity of propagation

66 % (5 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

25 mm

0.98 inch

weight

48 g / m

0.0320 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +85 °C

-40 / +185 °F

fire resistance

no

halogen free

no

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

0.05

0.10

0.03

300

0.1

0.14

0.04

212

0.2

0.20

0.06

150

0.3

0.25

0.08

122

0.5

0.33

0.10

95

0.6

0.36

0.11

86

0.7

0.40

0.12

80

0.8

0.43

0.13

75

1.0

0.48

0.15

67

attenuation calculation (dB/m)

(0.44 x √f GHz) + (0.04 x f GHz)

power calculation (W)

67 / √f GHz

(1)

PE = PolyEthylene

(2)

PVC = PolyVinyl Chloride

Cost effective solution

p/N: C291 351 012

(NF-C-93/550-KX6)

Advertising