Cable assemblies, Low loss flexible cable 10/50 d, Eco393x) – Northern Connectors Radiall RF & Microwave Cable Assemblies User Manual

Page 23: Construction / dimensions, Electrical characteristics, Mechanical characteristics, Environmental characteristics

Advertising
background image

www.radiall.com

B-24

Cable assemblies

lOW lOSS flEXIblE CablE

10/50 D

(ECO393: alternative to RG393)

: Service+ program = fast delivery

Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

solid OFC

(1)

2.40

0.094

dielectric

foam PE

(2)

7.25

0.285

inner shield

Al

(3)

foil

7.35

0.289

outer shield

TC

(4)

braid

7.85

0.309

jacket

black LSZH PE

(5)

9.10

0.358

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 2Ω

operating frequency range

DC - 3 GHz

shielding effectiveness

80 dB (DC - 3 GHz)

voltage withstanding

10 000 V rms

peak power

6.6 kW

capacitance

88 pF / m

26.6 pF / ft

velocity of propagation

75 % (4.4 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

40 mm

1.57 inch

weight

130 g / m

0.0875 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +85 °C

-40 / +185 °F

fire resistance

yes (UL1581 VW1 / IEC 332-1)

halogen free

yes (IEC 754-2)

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

0.1

0.05

0.01

1 265

0.2

0.07

0.02

894

0.3

0.08

0.03

730

0.5

0.11

0.03

566

1.0

0.16

0.05

400

1.5

0.20

0.06

327

2.0

0.24

0.07

283

2.5

0.27

0.08

253

3.0

0.30

0.09

231

attenuation calculation (dB/m)

(0.14 x √f GHz) + (0.02 x f GHz)

power calculation (W)

400 / √f GHz

(1)

OFC = Oxygen Free Copper

(2)

PE = PolyEthylene

(3)

Al = Aluminum

(4)

TC = Tinned Copper

(5)

LSZH PE = Low Smoke Zero Halogen PolyEthylene

Designed by RADIALL, ECO393 is an
advantageous alternative solution to RG393:

• Advantageous in term of electrical
performance:

its optimized construction allows

better attenuation and screening effectiveness
than RG393

• Advantageous in term of environmental
aspect:

halogen and sulphur free, this cable

does not emit any toxic substance when
submitted to fire.
The flame retardant jacket allows ECO393 to
meet fire resistance standards.

• Advantageous in term of price:

ECO393

design has integrated all RADIALL knowledge
to reach the best performance with a very
competitive price.
ECO393 is UL style 1375 approved.

This cable is compatible with a large range of
connector series.

ECO-Friendly cable
Cost effective solution

APPLICATION NOTE

p/N: C291 491 060

lOW lOSS flEXIblE CablE

10/50 D

(ECO393X)

p/N: C291 512 020

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

stranded SPC

(1)

2.35

0.093

dielectric

X foam PE

(2)

7.20

0.283

inner shield

SPC

(1)

braid

7.89

0.311

outer shield

SPC

(1)

braid

8.57

0.337

jacket

black LSZH PE

(3)

10.00

0.394

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 2Ω

operating frequency range

DC - 6 GHz

shielding effectiveness

78 dB (DC - 3 GHz)

voltage withstanding

5 000 V rms

capacitance

94 pF / m

28.1 pF / ft

velocity of propagation

71 % (4.7 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

50 mm

1.97 inch

weight

180 g / m

0.120 Ibs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +105 °C

-40 / +221 °F

fire resistance

yes (UL1581 VW1)

halogen free

yes (IEC 754-2)

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

0.5

0.18

0.05

693

1.0

0.29

0.09

490

1.5

0.38

0.12

400

2.0

0.47

0.14

346

2.5

0.56

0.17

310

3.0

0.64

0.19

283

3.5

0.72

0.22

262

4.0

0.80

0.24

245

5.0

0.96

0.29

219

6.0

1.11

0.34

200

attenuation calculation (dB/m)

(0.17 x √f GHz) + (0.115 x f GHz)

power calculation (W)

490 / √f GHz

(1)

SPC = Silver Plated Copper

(2)

X foam PE = Crosslink foam PolyEthylene

(3)

LSZH PE = Low Smoke Zero Halogen PolyEthylene

Designed by RADIALL, ECO393X is an
advantageous alternative solution to ECO393
when higher power level is required:
• Advantageous in term of electrical performance:
the crosslink foam polyethylene used as
dielectric material allows higher temperature
level (thus power range) than ECO393.
• Advantageous in term of environmental
aspect:

halogen and sulphur free, this cable

does not emit any toxic substance when
submitted to fire. The flame retardant jacket
allows ECO393X to meet fire resistance
standards.
• Advantageous in term of price:

ECO393X

design has integrated all RADIALL knowledge
to reach the best performances with a very
competitive price.
ECO393X is UL style 3651 approved.
This cable is compatible with a large range
of standard connector series.

ECO-Friendly cable
Cost effective solution

APPLICATION NOTE

Advertising