B-34

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

solid SPC

(1)

0.92

0.036

dielectric

solid PTFE

(2)

2.98

0.117

inner shield

SPC

(1)

tubing

3.58

0.141

outer shield

-

-

-

jacket

-

-

-

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 1Ω

operating frequency range

DC - 20 GHz

shielding effectiveness

110 dB

voltage withstanding

5 000 V rms

peak power

3.4 kW

capacitance

89 pF / m

27 pF / ft

velocity of propagation

70 % (4.8 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

1.90 mm

0.075 inch

weight

46 g / m

0.0309 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +125 °C

-40 / +257 °F

fire resistance

not applicable

halogen free

no

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

1.0

0.34

0.10

315

2.0

0.50

0.15

223

3.0

0.64

0.19

182

6.0

0.97

0.30

129

8.0

1.17

0.35

111

10.0

1.35

0.41

100

12.4

1.55

0.47

89

18.0

1.99

0.60

74

20.0

2.14

0.65

70

attenuation calculation (dB/m)

(0.30 x √f GHz) + (0.04 x f GHz)

power calculation (W)

315 / √f GHz

(1)

SPC = Silver Plated Copper

(2)

PTFE = PolyTetraFluoroEthylene

Based on RG402 standard, this cable is used
where non magnetic aspect is required.

In addition, due to the outer conductor
coating (silver), this cable will be used
instead of RG402 for applications requiring
high corrosion resistance and improved
solderability.

APPLICATION NOTE

Cable assemblies

SEmI-RIgID CablE .141

(Silvered copper)

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

solid SPC

(1)

0.92

0.036

dielectric

solid PTFE

(2)

2.98

0.117

inner shield

copper tubing

3.58

0.141

outer shield

-

-

-

jacket

-

-

-

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 1Ω

operating frequency range

DC - 20 GHz

shielding effectiveness

110 dB

voltage withstanding

5 000 V rms

peak power

3.4 kW

capacitance

89 pF / m

27 pF / ft

velocity of propagation

70 % (4.8 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

2.54 mm

0.100 inch

weight

46 g / m

0.0309 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +125 °C

-40 / +257 °F

fire resistance

not applicable

halogen free

no

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

1.0

0.34

0.10

315

2.0

0.50

0.15

223

3.0

0.64

0.19

182

6.0

0.97

0.30

129

8.0

1.17

0.35

111

10.0

1.35

0.41

100

12.4

1.55

0.47

89

18.0

1.99

0.60

74

20.0

2.14

0.65

70

attenuation calculation (dB/m)

(0.30 x √f GHz) + (0.04 x f GHz)

power calculation (W)

315 / √f GHz

(1)

SPC = Silver Plated Copper

(2)

PTFE = PolyTetraFluoroEthylene

Based on RG402 standard, this cable is used
where non magnetic aspect is required.

APPLICATION NOTE

SEmI-RIgID CablE .141

(Non magnetic)

p/N: C291 861 061

p/N: C291 861 066

Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)