B-28

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

solid AlCC

(1)

3.60

0.142

dielectric

foam PE

(2)

8.30

0.327

corrugated inner shield

spiral copper tube

12.30

0.484

outer shield

-

-

-

jacket

black LSZH PE

(3)

13.50

0.531

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 1Ω

operating frequency range

DC - 11.7 GHz

shielding effectiveness

110 dB

voltage withstanding

5 845 V rms

peak power

20.5 kW

capacitance

82 pF / m

24.8 pF / ft

velocity of propagation

82 % (4.1 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

32.0 mm

1.260 inch

weight

210 g / m

0.140 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +85 °C

-40 / +185 °F

fire resistance

yes (UL 1581 VW1 / IEC 332-1)

halogen free

yes (IEC 754-2)

fREqUENCy / aTTENUaTION (typ. / 25 °C) /

CW maX pOWER (sea level / 40 °C)

GHz

dB / m

dB / ft

Watts

0.5

0.08

0.02

1 120

1.0

0.11

0.03

770

1.5

0.14

0.04

616

2.0

0.16

0.05

525

2.5

0.18

0.06

461

3.0

0.20

0.06

417

4.0

0.24

0.07

353

6.0

0.30

0.09

278

8.0

0.36

0.11

234

10.0

0.42

0.13

204

attenuation calculation (dB/m)

(0.10 x √f GHz) + (0.01 x f GHz)

(1)

AlCC = Aluminum Covered Copper

(2)

PE = PolyEthylene

(3)

LSZH PE = Low Smoke Zero Hallogen PolyEthylene

The outer conductor of this cable is constituted
of a corrugated tube (spiral winding).

This construction allows perfect shielding and
bendability while respecting large bending radius.

The foam dielectric provides excellent loss and
low return loss levels.

This cable will be advised for feeder and jumper
assemblies in cellular networks as well as
applications requiring high performance level
on long distances.

The anti-UV LSZH (Low Smoke Zero Hallogen)
material is also flame retardant and allows this
cable to be used for indoor public areas as well
as outoor installations.

APPLICATION NOTE

CORRUgaTED CablE 1/2"

(Cellflex 1/2" Spiral)

p/N: C291 994 170

(Cellflex HCF 1/2" CuH-50 AlCu)

This is the smallest semi-rigid cable size
proposed by RADIALL.

Its reduced size allows it to be easily
handformable during integration operations.

APPLICATION NOTE

Cable assemblies

SEmI-RIgID CablE .047

(Copper)

Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

solid SPCCS

(1)

0.29

0.011

dielectric

solid PTFE

(2)

0.94

0.037

inner shield

copper tubing

1.19

0.047

outer shield

-

-

-

jacket

-

-

-

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 2.5Ω

operating frequency range

DC - 20 GHz

shielding effectiveness

110 dB

voltage withstanding

2 000 V rms

peak power

1.1 kW

capacitance

100 pF / m

30 pF / ft

velocity of propagation

70 % (4.8 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

3.17 mm

0.125 inch

weight

6.0 g / m

0.0040 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +100 °C

-40 / +212 °F

fire resistance

not applicable

halogen free

no

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

1.0

1.14

0.35

30

2.0

1.64

0.50

21

3.0

2.03

0.61

17

6.0

2.93

0.89

12

8.0

3.43

1.04

11

10.0

3.88

1.18

9.5

12.4

4.37

1.32

8.5

18.0

5.39

1.63

7.1

20.0

5.72

1.73

6.7

attenuation calculation (dB/m)

(1.10 x √f GHz) + (0.04 x f GHz)

power calculation (W)

30 / √f GHz

(1)

SPCCS = Silver Plated Copper Covered Steel

(2)

PTFE = PolyTetraFluoroEthylene

p/N: C291 855 001

(MIL-C-17/151-00001)