Debugging or listening?
The built-in speaker on the rear side gives the acoustical response of

the measured signal – everywhere and any time – without the need

of a headphone. For the users convenience a good headphone may

be connected for listening in superior quality (up to 24 bit / 96 kHz).

The headphone output may be used as D/A converter, e.g. some

recording with a minidisc-player is requested but no analog output

is available.

oops – no signal!
Often no signal is found during troubleshooting at digital audio lines.

Can this be? The Digilyzer offers a digital realized “AGC” (automatic

gain control) to “zoom up” the digital signal. So even a change of the

LSB (least significant bit) is fully audible. The tremendous dynamic

range of

140 dB allows to listen to the smallest disturbances. For

example someone just has closed the fader or muted the signal, so

just activate the AGC and listen; even dither noise will be audible.

All the above monitoring functionalities can be controlled by using

hotkeys, displayed in the FAST ACCESS SETUP menu.

dual domain measurements
Level RMS and distortion (THD+N) measurements are fundamental to

check A/D converters. The complete test system even checks mixed

mode applications such as A/D converters or digital mixers is available

in combination with the analog signal generator Minirator MR1.