8. AppeNdIx

1C2f Format

The AES3 standard includes the following two options for 96 kHz

sample rate operation:

• To double the frame rate from the previous 48 kHz to 96 kHz

(not possible for older equipment). This is the normal operation

of the Digilyzer.

• Using the two sub-frames (two channels) of a 48 kHz frame

rate AES3 signal to carry consecutive samples of a mono signal

resulting in a 96 kHz sample rate stream. The samples of one

96 kHz signal are packed “interleaved” into two 48 kHz signals.

This allows older equipment, which transmitters and receivers

are not rated for 96 kHz frame rate operation, to handle 96 kHz

sample rate information.

This mode is called “single channel double frequency mode” or

“double wire mode” (two AES3 cables are needed for stereo).

The Digilyzer also enables measurements in this mode. Just

select the input format 1C2f and the input channel menu will

indicate “A

i B” (or eg. “1 i 2” for ADAT). This indicates that

channel A and B are used in an interleaved manner (1C2f

mode).

The Digilyzer is specified for samples rates up to 96 kHz, so for

a 1C2f signal the resulting sample frequency shall not exceed

this value.