Consistency check, Channel status details – NTi Audio Digilyzer DL1 User Manual

Page 31

Advertising
background image

31

Consistency Check

The consistency check is constantly running as a background task. It

compares the carrier information with the status information. E.g. the

sampling frequency claims to be 44.1 kHz but in reality is 48.0 kHz.

Such errors are immediately displayed via a flashing square around

the individual status information.

The consistency check is carried out with the following parameters:

• Sample frequency

• Word length

• Clock accuracy

• 1C2f usage

Channel Status Details

Detailed information about the interpretation of each individual bit and

bytes may be found in the normative documents IEC 60958-3 and

AES3. A summary is given in the appendix.

Measurement Functions

Fig 5-06, Channel status consistency check

Wrong sample

frequ. status

information

Measured

sampling

frequency

Application hints:

• Wrong signalization of the sample frequency of digital audio

devices may cause real trouble.

• Some units expected to be e.g. 24 bit devices, signalize 24

bit in the channel status but only send 22 relevant bits. The

consistency check helps to see this problems quick and

easy.